Cleanroom Differential Pressure Monitoring

Measure, display and alarm on the pressure difference between controlled rooms and adjacent areas, then send the values to your building management, PLC or remote monitoring system with POLWAX differential pressure transmitters.

  • Bi-directional ranges
  • Local display & alarm
  • 4–20 mA · 0–10 V · RS485 Modbus RTU
POLWAX DPT30 panel-mount differential pressure transmitter
DPT30 Differential Pressure Transmitter

The Challenge

Keeping air moving in the right direction

Cleanrooms and controlled areas rely on a defined pressure relationship with the rooms around them, so that air flows from cleaner areas towards less clean ones. Door openings, filter loading and changes in the ventilation system can all disturb that balance.

The pressure differences involved are small, so they need instruments that resolve low ranges, show the value at the room and warn staff when the relationship is lost.

  • Continuous indication of room-to-room pressure difference
  • Local alarm when the pressure relationship is not maintained
  • Values available to BMS, PLC or remote monitoring for records
  • Related room conditions such as temperature and humidity
Illustrative pressure cascade: cleanroom at the highest pressure, airlock in between and corridor at the lowest pressure, with air flowing outward and transmitters measuring each difference Cleanroom highest pressure Airlock intermediate Corridor lowest pressure + + + Air flows from cleaner to less clean areas ΔP ΔP Illustration only. Set points depend on your room classification and design.
A typical pressure cascade, with a differential pressure transmitter measuring each room-to-room difference.

The POLWAX Solution

Measure, indicate, alarm and integrate

POLWAX DPT series transmitters measure the pressure difference between two points through 3/16" tubing, show it in Pa or mmWC and pass it on in the form your system needs.

  • Measure

    Low, bi-directional differential pressure ranges starting from 0–10 mm WC on the DPT20 and DPT30.

  • Indicate

    Local reading at the room, in Pa or mmWC, configured with the front keys or, on the DPT50 WM, via USB.

  • Alarm

    Inbuilt buzzer on DPT20 and DPT30 alarm versions, and a relay option on the DPT30 for external signalling.

  • Integrate

    4–20 mA, 0–10 V and RS485 Modbus RTU options to connect to BMS, PLC or the CloudWAY IoT gateway.

How It Works

From the room to your monitoring system

  1. Pressure taps

    Tubing connects the cleanroom and the reference area to the transmitter's push-on 3/16" ports.

  2. Transmitter

    A DPT series transmitter measures the difference and shows it locally in Pa or mmWC.

  3. Local alarm

    Alarm versions sound a buzzer; the DPT30 relay option can switch an external signal.

  4. Signal output

    4–20 mA, 0–10 V or RS485 Modbus RTU, depending on the model and order code.

  5. Monitoring

    Values go to your BMS, PLC or SCADA, or through a CloudWAY gateway over WiFi, Ethernet or GSM.

Add a ClimaTRANS RHT100 in the same room to send temperature and humidity over the same RS485 Modbus RTU network.

Recommended Products

POLWAX instruments for cleanroom pressure monitoring

Specifications are taken from the POLWAX product pages and may change. Please check the current datasheet or ask our team before ordering.

  • POLWAX DPT20 differential pressure transmitter
    Differential pressure

    DPT20 Differential Pressure Transmitter

    Panel-mount transmitter with an inbuilt buzzer or 4–20 mA output, for room and filter pressure monitoring.

    Ranges
    0–10 to 0–250 mm WC, bi-directional
    Accuracy
    ±0.5 % FS (ranges ≥ 0–25 mm WC); ±1.0 % FS (≤ 0–10 mm WC)
    Output
    Inbuilt buzzer / 4–20 mA; 0–10 V optional
    Supply
    12–24 VDC · panel mounting
    View DPT20 details
  • POLWAX DPT30 differential pressure transmitter
    Differential pressure

    DPT30 Differential Pressure Transmitter

    Extends the DPT20 platform with wider ranges and more output options, including RS485 Modbus RTU and relay.

    Ranges
    0–10 to 0–700 mm WC, bi-directional
    Accuracy
    ±0.5 % FS (ranges ≥ 0–25 mm WC); ±1.0 % FS (≤ 0–10 mm WC)
    Outputs
    Alarm (buzzer), 0–10 V, 4–20 mA, relay, RS485 Modbus RTU (order options)
    Units
    Pa & mmWC · response time 500 ms
    View DPT30 details
  • POLWAX DPT50 WM high-precision differential pressure transmitter
    Differential pressure

    DPT50 WM / DPT100 WM / DPH100 WM

    High-precision transmitters configured via USB; the DPH100 WM also measures temperature and humidity.

    Accuracy
    0.25 % / 0.5 % of FS
    Outputs
    4–20 mA (std.), 0–10 V (optional), RS485 Modbus RTU
    Config
    USB interface · selectable pressure units
    DPH100 WM
    T: -30 to 80 °C · RH: 0–100 %
    View DPT50 WM details
  • POLWAX ClimaTRANS RHT100 temperature and humidity transmitter
    Temperature & humidity

    ClimaTRANS RHT100

    Industrial temperature and humidity transmitter with TFT display for the same controlled rooms.

    Accuracy
    ±0.3 °C (0–60 °C) · ±1.8 % RH at 23 °C (0–90 % RH)
    Output
    RS485 Modbus RTU
    Display
    TFT · wall or duct mount
    Protection
    IP65
    View RHT100 details
  • POLWAX CloudWAY IoT gateway
    Connectivity

    CloudWAY IoT Gateway GT400 / GT800

    Connects 4–20 mA and Modbus RS485 transmitters to remote monitoring.

    Channels
    4 (GT400) / 8 (GT800)
    Inputs
    4–20 mA / Modbus RS485
    Network
    WiFi / Ethernet / GSM
    Protocols
    MQTT, Modbus, HTTP
    View CloudWAY details
  • POLWAX Product recommendation
    Not sure which model?

    Get a recommendation

    Tell us the number of rooms, the pressure range you expect, whether you need a local alarm and how the values should reach your system. Our team will suggest suitable models and options.

    Contact our team

Key Benefits

Why use POLWAX for cleanroom pressure

  • Bi-directional ranges

    All DPT20 and DPT30 ranges are bi-directional, so a reversal of the pressure relationship is still measured.

  • Alarm at the room

    Buzzer versions alert staff on site, without depending on a remote system.

  • Flexible integration

    Analogue, relay and RS485 Modbus RTU options to suit BMS, PLC and SCADA systems.

  • Calibration certificate supplied

    The DPT20, DPT30, DPT50 WM and RHT100 are each supplied with a calibration certificate and manual.

  • Complete room picture

    Combine pressure with temperature and humidity using the RHT100 or the DPH100 WM.

  • Remote monitoring option

    The CloudWAY gateway sends transmitter values over WiFi, Ethernet or GSM.

Industries & Use Cases

Where differential pressure monitoring is used

  • Pharmaceutical & biotech cleanrooms

    Room-to-room pressure, airlocks and controlled production areas.

  • Laboratories & research facilities

    Controlled lab rooms that depend on a defined pressure relationship.

  • HVAC & air handling

    Filter loading, fan and airflow monitoring that keep cleanroom supply air stable.

  • Building automation

    Pressure values fed into BMS for smart ventilation control and records.

Product suitability depends on the model, configuration and the requirements of your facility, including any regulatory or validation requirements. Please contact our team to confirm the right instrument for your application.

Technical Resources

Datasheets and documentation

Datasheets and manuals for these products are available on request.

  • DPT20 datasheetTechnical Resources
    Resources
  • DPT30 datasheetTechnical Resources
    Resources
  • DPT50 WM series datasheetTechnical Resources
    Resources
  • ClimaTRANS RHT100 datasheetTechnical Resources
    Resources

FAQ

Frequently asked questions

Which model gives a local alarm at the room?

The DPT20 is available with an inbuilt buzzer, and the DPT30 offers an alarm with inbuilt buzzer plus a relay output option. The output type is selected by order code.

Can the pressure readings go to our BMS or PLC?

Yes. The DPT30 offers 4–20 mA, 0–10 V and RS485 Modbus RTU options; the DPT50 WM series provides 4–20 mA as standard, 0–10 V as an option and RS485 Modbus RTU; the DPT20 offers 4–20 mA with 0–10 V optional.

What does bi-directional mean for cleanroom monitoring?

All DPT20 and DPT30 ranges are bi-directional, so the transmitter measures the pressure difference in both directions. If the intended relationship between two rooms reverses, the reading still shows it.

In which units are readings shown?

The DPT20 and DPT30 measure in Pa and mmWC. The DPT50 WM series has selectable pressure units, configured via its USB interface.

How accurate are the lowest ranges?

For the DPT20 and DPT30, accuracy is ±1.0 % of full scale for ranges up to 0–10 mm WC and ±0.5 % of full scale for ranges from 0–25 mm WC. The DPT50 WM series is specified at 0.25 % / 0.5 % of full scale.

Is a calibration certificate included?

The scope of supply listed for the DPT20, DPT30, DPT50 WM series and ClimaTRANS RHT100 includes a calibration certificate and a manual.

Can we monitor several rooms remotely?

The CloudWAY IoT gateway accepts 4 (GT400) or 8 (GT800) channels of 4–20 mA or Modbus RS485 instruments and communicates over WiFi, Ethernet or GSM using MQTT, Modbus or HTTP.

Plan your cleanroom pressure monitoring

Share your room layout, expected pressure range and integration needs, and our team will recommend suitable POLWAX instruments.