Solution · Pharmaceutical & Biotech
Pharmaceutical & Biotechnology Monitoring
Record and follow the temperature of sensitive materials in laboratory refrigerators, freezers, ultra-low temperature storage, cold rooms and shipments, with POLWAX connected dataloggers, USB loggers, freeze indicators and the CloudDASH360 cloud dashboard.
- Fridges, freezers & cold rooms
- Probe ranges down to −90 °C
- Alarms by dashboard, SMS & email
Monitoring Challenges
Temperature-sensitive materials need a dependable record
Medicines, vaccines, biologics, reagents and research samples are stored and moved at defined temperatures. Teams need to know that those conditions were held, and to see quickly when they were not.
-
Complete temperature records
A continuous history for every fridge, freezer, room and shipment, available as a report when it is needed.
-
Visibility of excursions
Knowing when a limit was crossed, ideally while there is still time to act on it.
-
Many storage points
Laboratories, stores and facilities often hold materials across many units and locations at once.
-
Conditions in transit
Shipments between sites, including dry-ice consignments, need their own record from dispatch to arrival.
The POLWAX Approach
The right type of monitoring for each point
POLWAX combines four types of instrument, so each storage unit or shipment gets the level of monitoring it needs.
-
Connected monitoring
CLIMA dataloggers send readings over WiFi, GSM or Ethernet to the optional CloudDASH360 dashboard for remote viewing and alarms.
-
Reusable USB logging
PTD50 / PRH50 and PTE50 / PTE90 loggers record locally and produce PDF or CSV reports when connected to USB.
-
Single-use for shipments
PTRANS loggers travel with the goods; the TD90 version is intended for dry-ice shipments.
-
Freeze indication
PolSENSE shows √ or × at a glance if freeze-sensitive goods have been exposed to freezing.
How It Works
Two ways to monitor, one clear record
Connected monitoring
CLIMA datalogger + CloudDASH360- Measure
Internal or external sensors on 1, 2 or 4 channels.
- Record & display
Readings on the colour touch-screen; configuration is password protected.
- Transmit
Data sent at set intervals over WiFi, GSM or Ethernet.
- Review & alert
CloudDASH360 shows data and raises alarms on the dashboard, by SMS and by email.
Standalone USB logging
PTD50 / PRH50 · PTE50 / PTE90 · PTRANS- Configure
Set interval, start mode and alarm limits in the Polwax Config web application.
- Record
The logger records in the fridge, freezer or shipment; LED shows green (OK) or red (alarm).
- Connect
Plug the logger into a computer USB port.
- Report
A PDF and/or CSV report is generated for review and filing.
Selection Guide
Which POLWAX product for which application?
A starting point based on published product specifications. Our team can confirm the right model for your units and temperatures.
| Application | POLWAX product | Published range | Data access |
|---|---|---|---|
| Lab refrigerators & cold rooms with remote alerts | CLIMA datalogger + CloudDASH360 | TH models: −40 to +70 °C, 0–100 % RH · T models: Pt100 −100 to 400 °C | WiFi / GSM / Ethernet; dashboard, SMS & email alarms |
| Freezers & ultra-low temperature storage | PTE50 / PTE90 | −50~70 °C / −90~70 °C (probe) | USB 2.0; PDF / CSV report |
| Storage areas & reusable cold-chain logging | PTD50 / PRH50 | −30 to 70 °C (PRH50: + 0–100 % RH) | USB 2.0; PDF / CSV; up to 6 alarm limits |
| Shipments between sites | PTRANS T10 / TD10 / T20 / RH20 | −30 to 70 °C (RH20: + 0–100 % RH) | USB 2.0; report without additional software |
| Dry-ice shipments | PTRANS TD90 | −90 ~ 70 °C | USB 2.0 |
| Freeze-sensitive goods | PolSENSE-G / -O | Factory-preset freeze alarm · ±0.3 °C typ. | √ / × indication on the device |
| Controlled rooms connected to BMS | ClimaTRANS RHT100 | ±0.3 °C (0–60 °C) · ±1.8 % RH at 23 °C | RS485 Modbus RTU to BMS / PLC / SCADA |
Recommended Products
POLWAX products for pharmaceutical and biotech monitoring
Specifications are taken from the POLWAX product pages and may change. Please check the current datasheet or ask our team before ordering.
-
Connected dataloggerCLIMA Datalogger (WiFi, GSM, Ethernet)
1, 2 or 4-channel temperature or temperature/humidity logger with colour touch-screen.
- Range
- TH: −40 to +70 °C, 0–100 % RH · T: Pt100 −100 to 400 °C
- Accuracy
- ±0.3 °C / ±2 % RH (at 5–95 %)
- Reports
- .PDF / .CSV / .XLSX
- Protection
- IP65 · password-protected configuration
-
Ultra-low temperaturePTE50 / PTE90 Ultra-Low Temperature Datalogger
Reusable USB logger with external probe and display for freezers and ultra-low storage.
- Range
- PTE50: −50~70 °C · PTE90: −90~70 °C (probe)
- Accuracy
- ±0.4 °C
- Memory
- Up to 33,000 points
- Report
- Automatic PDF / CSV via USB 2.0
-
Multi-use dataloggerPTD50 / PRH50 Multi-Use Datalogger
Reusable temperature (PTD50) and temperature/humidity (PRH50) USB loggers with display.
- Range
- −30 to 70 °C (PRH50: + 0–100 % RH)
- Accuracy
- ±0.4 °C @ −10~40 °C
- Alarms
- Up to 6 programmable alarm limits
- Battery
- Replaceable CR2450 · IP65
-
Single-use dataloggerPTRANS Single-Use Datalogger
T10, TD10, T20 and RH20 loggers for shipments: start with one button, plug into USB for the report.
- Range
- −30 to 70 °C (RH20: + 0–100 % RH)
- Accuracy
- ±0.4 °C @ −10~40 °C
- Interval
- 1 minute – 24 hours (selectable)
- Memory
- Up to 33,000 points · USB 2.0
-
Dry-ice shipmentsPTRANS TD90 Dry Ice Datalogger
Single-use temperature datalogger with display for dry-ice and ultra-low temperature transport.
- Range
- −90 °C ~ 70 °C
- Memory
- Up to 33,000 points
- Battery
- 3.6 V lithium
- Interface
- USB 2.0
-
Freeze indicatorPolSENSE Electronic Freeze Indicator
Always-active indicator for vaccines, pharmaceuticals, biologics and medical samples.
- Indication
- √ / × · factory-preset freeze alarm
- Accuracy
- ±0.3 °C typ.
- Shelf life
- Up to 5 years
- Protection
- IP67 · 23 g
-
Room transmitterClimaTRANS RHT100
Temperature and humidity transmitter with TFT display for controlled rooms connected to BMS.
- Accuracy
- ±0.3 °C (0–60 °C) · ±1.8 % RH at 23 °C
- Output
- RS485 Modbus RTU
- Mounting
- Wall or duct
- Protection
- IP65
-
Cloud softwareCloudDASH360 Cloud Dashboard
Optional cloud dashboard for CLIMA connected dataloggers.
- For
- CLIMA WiFi, GSM and Ethernet dataloggers
- Access
- Web app · mobile app (Android + iOS)
- Alarms
- Upper & lower threshold per variable, with hysteresis and delay
- Notify
- Cloud dashboard, SMS and email
-
Not sure which model?Get a recommendation
Tell us which units and shipments you need to monitor, the temperatures involved, how many points, and whether you need remote alarms or USB reports. Our team will suggest suitable POLWAX products.
Contact our team
Application Areas
Where POLWAX monitoring is used
-
Laboratory refrigerators & cold rooms
Continuous monitoring with CLIMA loggers and remote alarms through CloudDASH360.
-
Freezers & ultra-low temperature storage
PTE50 / PTE90 probe loggers, or CLIMA T models with external Pt100 sensors.
-
Pharmaceutical storage & distribution
PTD50 / PRH50 reusable loggers in stores and PTRANS loggers for outgoing consignments.
-
Biotech samples & dry-ice shipments
PTRANS TD90 for dry-ice transport and PTE90 for ultra-low storage.
-
Vaccines & biologics
PolSENSE freeze indicators alongside dataloggers for freeze-sensitive goods.
-
Controlled production areas
RHT100 room transmitters; for room pressure, see Cleanroom Differential Pressure Monitoring.
Product suitability depends on the model, its configuration and the requirements of your facility, including any regulatory, qualification or validation requirements. Please contact our team to confirm the right instrument for your application.
Key Benefits
What POLWAX brings to pharmaceutical monitoring
-
From storage to shipment
Connected loggers, reusable and single-use USB loggers and freeze indicators from one supplier.
-
Ultra-low coverage
Probe ranges down to −90 °C (PTE90, PTRANS TD90) and Pt100 inputs to −100 °C on CLIMA T models.
-
Remote alarms
CloudDASH360 notifies on the dashboard, by SMS and by email when a CLIMA reading crosses its thresholds.
-
Ready-made reports
USB loggers generate PDF or CSV reports; CLIMA exports PDF, CSV or XLSX.
-
Protected configuration
CLIMA logger settings can only be changed after entering a password.
-
Certificates supplied
CLIMA and RHT100 ship with a calibration certificate; PTD50, PTE and PTRANS loggers with a test certificate.
Technical Resources
Software and documentation
Datasheets and instruction manuals are available on request.
FAQ
Frequently asked questions
Which logger suits an ultra-low temperature freezer?
The PTE90 has an external probe that measures from −90 °C to 70 °C, and the PTE50 from −50 °C to 70 °C. For continuous connected monitoring, CLIMA T models use an external Pt100 sensor with a range of −100 to 400 °C.
How do we receive alarms when we are not on site?
CLIMA WiFi, GSM and Ethernet dataloggers can be used with the optional CloudDASH360 dashboard. It supports an upper and a lower threshold per variable, with configurable hysteresis and delay, and sends alarms on the dashboard, by SMS and by email.
Do the USB loggers need special software to read the data?
PTRANS loggers produce their report when plugged into a USB port, without additional software. PTD50 / PRH50 and PTE50 / PTE90 loggers generate PDF and/or CSV reports automatically over USB. Settings are made in the Polwax Config web application.
When should we choose single-use or reusable loggers?
PTRANS single-use loggers are designed for one-way shipments. PTD50 / PRH50 and PTE50 / PTE90 are multi-use loggers with a replaceable CR2450 battery, suited to repeated use in storage and transport.
Which products also measure humidity?
CLIMA TH models, the PRH50, the PTRANS-RH20 and the ClimaTRANS RHT100 measure both temperature and relative humidity.
Are certificates supplied with the instruments?
According to the POLWAX product pages, CLIMA dataloggers and the RHT100 are supplied with a calibration certificate, and PTD50 / PRH50, PTE50 / PTE90 and PTRANS loggers with a test certificate.
Do these products meet specific regulatory requirements?
The POLWAX product information does not state compliance with specific regulations or software validation standards. If your quality system has particular requirements for records, alarms or documentation, please contact our team to discuss them before selecting a product.
Plan your pharmaceutical monitoring
Tell us which fridges, freezers, rooms or shipments you need to monitor, and our team will recommend suitable POLWAX instruments.